50 HZ ANALOG PANEL LOAD BANKS

AP Series Advantages

  • Simple operation suitable for non-trained operators and personnel; no maintenance required
  • Suitable for workshop or airside operation; silent unit rated at < 70 dB(A) at 7m / 23Ft
  • Cant protection – load bank works only when positioned on flat horizontal surface
  • Fine load regulation knob as standard for complete series of 50 Hz AC load banks
  • Housing made of non-corrosive parts with component quality control by the manufacturer
  • High reliability with multiple thermal protection – extremely resistant to high temperature
  • Extra safety and isolated jack sockets for connecting external voltage measuring device
  • Short worldwide delivery period with tracking feature and insurance for all products
  • Spare parts availability and accurate on-time deliveries by appointed courier
  • Transport casing with pull up handle as standard for every load bank manufactured
  • 2 years full warranty with extension option for all DEKAL load banks
  • CE certification – health, safety, and environmental protection standards
  • Made for GPU’s testing procedure according to ISO 6858, DFS 400, ARP 5015
  • Classification CE marking, DIN, VDE, IEC, IP 21 protection rate level
  • Customs classification Harmonized System tariff code HS: 8516808000

50 Hz LOAD BANKS - ANALOG PANEL

Select an available model:

TECHNICAL SPECIFICATION
ALB-50-80AP
VOLTAGE [V] * FREQUENCY [Hz]
420 / 240 V AC ± 5 % * 50 Hz ± 20 %
LOAD / POWER [kW / kVA cosφ=1]
0 – 80 kW ± 10 %
RATE SWITCH REG. LOAD STEPS ± 5%
ROUGH ADJUSTMENTS 7.5 Kw STEPS
POWER [kW / kVA cosφ=1]
10 SEQUENCE STEPS:
0 – 7.5 kW
7.5 – 15.0 kW
15.0 – 22.5 kW
22.5 – 30.0 kW
30.0 – 37.5 kW
37.5 – 45.0 kW
52.5 – 60.0 kW
60.0 – 67.5 kW
67.5 – 75.0 kW
75.0 – 82.5 kW
FORCED AIR COOLING [m³/min & CFM]
88.20 m³/min – 3120 CFM
INDICATIONS
ANALOGUE VOLT METER
ANALOGUE AMPERE METER
ANALOGUE FREQUENCY METER
VOLT METER – MOVING IRON CLASS 1.5
AMPERE METER – MOVING IRON CLASS 1.5
FREQUENCY METER – MOVING IRON CLASS 0.5
TYPE OF CONNECTION
CAMLOCK CONNECTOR for L1, L2, L3, N
GPU TESTING PROCEDURE*
*Proposal procedure:
LOAD raising from 0 100% 30 seconds;
HOLD at 100% 5 minutes;
LOAD decrease from 100 0% 10 minutes
ENGINE DECARBONISING*
*Proposal procedure:
LOAD raising from 0 100% 30 seconds;
HOLD at 100% 45 minutes;
LOAD decrease from 100 0% 15 minutes
DIMENSIONS & WEIGHT
LOAD BANK SIZE [L x W x H] mm / Kg
LOAD BANK SIZE [L x W x H] In / Lbs
700 x 230 x 630 / 43
27.5 x 9.05 x 24.8 / 95
TRANSPORT CASING [L x W x H] mm / Kg
TRANSPORT CASING [L x W x H] In / Lbs
770 x 290 x 860 / 21
30.3 x 11.4 x 33.9 / 46
LOAD BANK PAINTING / TRANSPORT CASING
FINE POWDER COATING STRUCTURE DRYLAC® 29_80081 / ALUMINIUM FRAME WITH BLACK LAMINATED PLYWOOD PANEL
Including transport carrying case per unit / All specifications are subject to change without further notice
TECHNICAL SPECIFICATION
ALB-50-100AP
VOLTAGE [V] * FREQUENCY [Hz]
420 / 240 V AC ± 5 % * 50 Hz ± 20 %
LOAD / POWER [kW / kVA cosφ=1]
0 – 105 kW ± 10 %
RATE SWITCH REG. LOAD STEPS ± 5%
ROUGH ADJUSTMENTS – 8 kW STEPS
POWER [kW / kVA cosφ=1]
10 SEQUENCE STEPS:
0 – 7.5 kW
7.5 – 15.0 kW
15.0 – 22.5 kW
22.5 – 30.0 kW
30.0 – 37.5 kW
37.5 – 45.0 kW
52.5 – 60.0 kW
60.0 – 67.5 kW
67.5 – 75.0 kW
75.0 – 82.5 kW
60.0 – 67.5 kW
82.5 – 90.0 kW
90.0 – 97.5 kW
97.5 – 105 kW
FORCED AIR COOLING [m³/min & CFM]
88.20 m³/min – 3120 CFM
INDICATIONS
ANALOGUE VOLT METER
ANALOGUE AMPERE METER
ANALOGUE FREQUENCY METER
VOLT METER – MOVING IRON CLASS 1.5
AMPERE METER – MOVING IRON CLASS 1.5
FREQUENCY METER – MOVING IRON CLASS 0.5
TYPE OF CONNECTION
CAMLOCK CONNECTOR for L1, L2, L3, N
GPU TESTING PROCEDURE*
*Proposal procedure:
LOAD raising from 0 > 100% 30 seconds;
HOLD at 100% 5 minutes;
LOAD decrease from 100 > 0% 10 minutes
ENGINE DECARBONISING*
*Proposal procedure:
LOAD raising from 0 > 100% 30 seconds;
HOLD at 100% 45 minutes;
LOAD decrease from 100 > 0% 15 minutes
DIMENSIONS & WEIGHT
LOAD BANK SIZE [L x W x H] mm / Kg
LOAD BANK SIZE [L x W x H] In / Lbs
700 x 230 x 630 / 43
27.5 x 9.05 x 24.8 / 95
TRANSPORT CASING [L x W x H] mm / Kg
TRANSPORT CASING [L x W x H] In / Lbs
770 x 290 x 860 / 21
30.3 x 11.4 x 33.9 / 46
LOAD BANK PAINTING / TRANSPORT CASING
FINE POWDER COATING STRUCTURE DRYLAC® 29_80081 / ALUMINIUM FRAME WITH BLACK LAMINATED PLYWOOD PANEL
Including transport carrying case per unit / All specifications are subject to change without further notice
TECHNICAL SPECIFICATION
ALB-50-120AP
VOLTAGE [V] * FREQUENCY [Hz]
420 / 240 V AC ± 5 % * 50 Hz ± 20 %
LOAD / POWER [kW / kVA cosφ=1]
0 – 120 kW
RATE SWITCH REG. LOAD STEPS ± 5%
ROUGH ADJUSTMENTS – 8 kW STEPS
POWER [kW / kVA cosφ=1]
10 SEQUENCE STEPS:
0 – 7.5 kW
7.5 – 15.0 kW
15.0 – 22.5 kW
22.5 – 30.0 kW
30.0 – 37.5 kW
37.5 – 45.0 kW
52.5 – 60.0 kW
60.0 – 67.5 kW
67.5 – 75.0 kW
75.0 – 82.5 kW
60.0 – 67.5 kW
82.5 – 90.0 kW
90.0 – 97.5 kW
97.5 – 105 kW
105 – 112.5 kW
112.5 – 120 kW
FORCED AIR COOLING [m³/min & CFM]
88.20 m³/min – 3120 CFM
INDICATIONS
ANALOGUE VOLT METER
ANALOGUE AMPERE METER
ANALOGUE FREQUENCY METER
VOLT METER – MOVING IRON CLASS 1.5
AMPERE METER – MOVING IRON CLASS 1.5
FREQUENCY METER – MOVING IRON CLASS 0.5
TYPE OF CONNECTION
CAMLOCK CONNECTOR for L1, L2, L3, N
GPU TESTING PROCEDURE*
*Proposal procedure:
LOAD raising from 0 > 100% 30 seconds;
HOLD at 100% 5 minutes;
LOAD decrease from 100 > 0% 10 minutes
ENGINE DECARBONISING*
*Proposal procedure:
LOAD raising from 0 > 100% 30 seconds;
HOLD at 100% 45 minutes;
LOAD decrease from 100 > 0% 15 minutes
DIMENSIONS & WEIGHT
LOAD BANK SIZE [L x W x H] mm / Kg
LOAD BANK SIZE [L x W x H] In / Lbs
700 x 230 x 630 / 43
27.5 x 9.05 x 24.8 / 95
TRANSPORT CASING [L x W x H] mm / Kg
TRANSPORT CASING [L x W x H] In / Lbs
770 x 290 x 860 / 21
30.3 x 11.4 x 33.9 / 46
LOAD BANK PAINTING / TRANSPORT CASING
FINE POWDER COATING STRUCTURE DRYLAC® 29_80081 / ALUMINIUM FRAME WITH BLACK LAMINATED PLYWOOD PANEL
Including transport carrying case per unit / All specifications are subject to change without further notice
error: Content is protected !!